Title of article
Effect of microstructure on non-linear behavior of ultrasound during low cycle fatigue of pearlitic steels
Author/Authors
S. Palit Sagar، نويسنده , , S. and Metya، نويسنده , , A.K. and Ghosh، نويسنده , , M. and Sivaprasad، نويسنده , , S.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2011
Pages
4
From page
2895
To page
2898
Abstract
Influence of microstructural changes on the second harmonics of sinusoidal ultrasonic wave during low cycle fatigue (LCF) deformation in pearlitic steel was studied. Fatigue tests were interrupted and at every interruption, non-linear ultrasonic (NLU) parameter (β) was determined. Microstructures of cyclically deformed specimens at various cycles were examined by transmission electron microscopy (TEM). The variation of β with fatigue cycles was correlated with the microstructural changes and the results were explained through the variation in dislocation morphology and carbon content of the steel.
Keywords
Low cycle fatigue , Non-linear ultrasonic , Dislocations , microstructure , Carbon steel