Title of article
An analytical approach to space charge distortions for time projection chambers
Author/Authors
Astrid Rossegger، نويسنده , , S. and Schnizer، نويسنده , , B. and Riegler، نويسنده , , W.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2010
Pages
3
From page
193
To page
195
Abstract
In a time projection chamber (TPC), the possible ion feedback and also the primary ionization of high multiplicity events result in accumulation of ionic charges inside the gas volume (space charge). This charge introduces electrical field distortions and modifies the cluster trajectory along the drift path, affecting the tracking performance of the detector. In order to calculate the track distortions due to an arbitrary space charge distribution in the TPC, novel representations of the Greenʹs function for a TPC geometry were worked out. This analytical approach finally permits accurate predictions of track distortions due to an arbitrary space charge distribution by solving the Langevin equation.
Keywords
Calibration , Greenיs function , Space charge , Time projection chamber
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
2010
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Record number
2170611
Link To Document