• Title of article

    High resolution TOF detector for hypernuclei lifetime measurement

  • Author/Authors

    Kim، نويسنده , , Y.D. and Bhang، نويسنده , , H. and Hashimoto، نويسنده , , O. and Maeda، نويسنده , , K. and Omata، نويسنده , , K. and Outa، نويسنده , , H. and Park، نويسنده , , H. Y. Youn، نويسنده , , M.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1996
  • Pages
    8
  • From page
    431
  • To page
    438
  • Abstract
    We have tested several types of TOF counters based on scintillators and photomultiplier tubes in order to measure the lifetime of hypernuclei. With the advantage of small counter size, we obtained less than 30 ps timing resolution, and about 50 ps overall TOF resolution. The various factors in this resolution have been studied. The timing resolution dependence on the beam intensity is also studied.
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    1996
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number

    2172341