Title of article
Correction of fast neutron scattered components from fast neutron radiography images
Author/Authors
Yoshii، نويسنده , , Koji and Kobayashi، نويسنده , , Hisao، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1996
Pages
4
From page
76
To page
79
Abstract
Fast Neutron Radiography (FNR) results have been successfully obtained by the use of the fast neutron source reactor YAYOI of the University of Tokyo. However, an effect of contrast distortion in the FNR images was observed. The intensity of scattered fast neutrons at the center of an object image was analyzed with a simple model of an iron cylindrical sample. Analytical results agreed well with experimental results.
Keywords
Contrast distortion , Fast neutron radiography , Scattered fast neutrons