Title of article
Measurements on transverse cooling times and beam profiles in CELSIUS
Author/Authors
Hedblom، نويسنده , , K and Hermansson، نويسنده , , L، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1997
Pages
5
From page
37
To page
41
Abstract
The CELSIUS accelerator ring is equipped with a magnesium jet profile monitor which has been used to study transverse electron cooling of ion beams. Cooling times were measured by using a theory which takes intrabeam scattering into account. The results agreed with the cooling times derived from the binary model. Mis-alignment between the electron and the ion beams was found to make a hole in the transverse beam emittance which could be observed as a double peak on the beam profile monitor. It was explained by negative cooling times for ions with small emittances.
Keywords
Intrabeam scattering , Monochromatic instability , Betatron oscillations , Transverse electron cooling
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
1997
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Record number
2175470