• Title of article

    The HARP liquid hydrogen system

  • Author/Authors

    van Uden، نويسنده , , M.A. and van der Meer، نويسنده , , R.L.J. and Bauer، نويسنده , , Th.S. and Bron، نويسنده , , M. and Buis، نويسنده , , R. and de Groen، نويسنده , , P.J.M. and Lefevere، نويسنده , , Y. and Nooren، نويسنده , , G.J.L. and Postma، نويسنده , , H. and van der Steenhoven، نويسنده , , G. and Willering، نويسنده , , H.W.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1999
  • Pages
    14
  • From page
    580
  • To page
    593
  • Abstract
    A liquid hydrogen system has been developed that serves as a scatterer for the High-Acceptance Recoil Polarimeter (HARP). In order to satisfy the conflicting design requirements regarding safety, the volume of the system, the energy loss of the recoiling protons, and the location of the cryogenic unit, a self-supporting thin-walled modular cryogenic system has been developed. The system was successfully operated during two commissioning runs of HARP in a high-luminosity electron scattering environment. The operational parameters of the system have been continuously monitored and are quantitatively understood.
  • Keywords
    neutron detection , Nucleon polarimetry , Liquid hydrogen system
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    1999
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number