• Title of article

    Position and size of the electron beam in the high-energy electron beam ion trap

  • Author/Authors

    Utter، نويسنده , , S.B. and Beiersdorfer، نويسنده , , P. and Lَpez-Urrutia، نويسنده , , J.R.Crespo and Widmann، نويسنده , , K.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1999
  • Pages
    8
  • From page
    276
  • To page
    283
  • Abstract
    In the last decade, many spectroscopic studies have been performed using the electron beam ion trap. Often these measurements rely on the electron beam as an effective slit, yet until now, no systematic study of the position and size of the electron beam under various operating conditions has been made. Here, we present a thorough study of the electron beamʹs position and size (and thus the electron density) as affected by various operating parameters, and give optimal parameter ranges for operating the device as a spectroscopic source. It is shown that the diameter is constant as the energy is varied, which is important for accurate cross-section measurements.
  • Keywords
    Helmholtz coils , Bucking coil current , EBIT , Spectroscopic measurements
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    1999
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number

    2181409