Acosta، نويسنده , , D and Apollinari، نويسنده , , G and Blomquist، نويسنده , , J and Breedon، نويسنده , , R and Bondar، نويسنده , , N and Bonushkin، نويسنده , , Yu and Borissov، نويسنده , , E and Bujak، نويسنده , , A and Bylsma، نويسنده , , B and Chester، نويسنده , , N and Chrisman، نويسنده , , D and Cline، نويسنده , , D and Dolinsky، نويسنده , , S and Durkin، نويسنده , , S and Eartly، نويسنده , , D and Ferguson، نويسنده , , T and Feyzi، نويسنده , , F and، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2000
Pages
6
From page
182
To page
187
Abstract
Presented are the main design features of the large Cathode Strip Chambers (CSCs) for the CMS Endcap Muon System as well as the performance results obtained with the two full-scale 3.4×1.5 m2 six-plane prototypes. The prototype performance was within the baseline requirements: (a) higher than 99% efficiency of muon track finding at the trigger level with more than 92% probability for bunch crossing identification and better than 2 mm spatial resolution, and (b) better than 150 μm spatial resolution in off-line.