• Title of article

    The precision drift chambers for the ATLAS muon spectrometer

  • Author/Authors

    Trefzger، نويسنده , , Thomas، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2000
  • Pages
    4
  • From page
    188
  • To page
    191
  • Abstract
    The parameters of the stand-alone muon system have been optimised to detect, also as a stand-alone system, the Standard Model Higgs boson as well as supersymmetric particles. The momentum resolution is typically 2–3% over most of the |η| range up to η=2.7. Above 200 GeV of transverse momentum (pT) position measurement and alignment errors begin to dominate and the resolution decreases to 10% at pT=1 TeV. The bulk of the magnet volume is instrumented with Monitored Drift Tubes 3 cm in diameter, each having a spatial resolution of typically 80 μm using an Ar–CO2 mixture at 3 bar.
  • Keywords
    Muon Spectrometer , ATLAS , quality control , Cosmic ray test stand , Drift tube , ALIGNMENT
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    2000
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number