Title of article
Degradation of pentachlorophenol aqueous solutions using a continuous flow ultrasonic reactor: experimental performance and modelling
Author/Authors
Gondrexon، نويسنده , , N and Renaudin، نويسنده , , V and Petrier، نويسنده , , C and Boldo، نويسنده , , P and Bernis، نويسنده , , A and Gonthier، نويسنده , , Y، نويسنده ,
Issue Information
فصلنامه با شماره پیاپی سال 1999
Pages
7
From page
125
To page
131
Abstract
The degradation of aqueous solutions of pentachlorophenol (PCP) in a three-stage sonochemical reactor operating in the continuous flow mode has been investigated. The experimental reactor may be considered as a series of three high-frequency ultrasonic units. The influence of several parameters such as ultrasonic power, reactor volume and volumetric feed flow rate on the reactor performance is reported. Application of classical basic chemical engineering principles leads to a model that enables us to predict the PCP concentration within the reactor. In steady state, experimental conversion rates are shown to be in good agreement with model predictions.
Keywords
High-frequency ultrasound , Multi-stage reactor , Pentachlorophenol , Scale-up , Sonochemical degradation process