Title of article
Study of THM-CdTe monolithic nuclear detectors matrix
Author/Authors
Hage-Ali، نويسنده , , M and Zumbiehl، نويسنده , , A and Koebel، نويسنده , , J.M and Régal، نويسنده , , R and Rit، نويسنده , , C and Ayoub، نويسنده , , M and Fougeres، نويسنده , , P and Siffert، نويسنده , , P، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2001
Pages
8
From page
68
To page
75
Abstract
In this paper we first discuss a few theoretical considerations, concerning the pixel effect and its optimisation. Starting from the weighting potential, which takes into account the pixel size on detector thickness ratio (W/L), we continue with a simple statistical approach, taking in account the photon absorption profile, the μτ parameters, the longitudinal and transversal carrier diffusion. This calculation has shown, for each μτ, an optimal W/L ratio. Experimental results show that Travelling Heather Method (THM) material is very suitable for monolithic matrix device, as well as Bridgman or CZT materials, and sometimes better, according to its good transport properties.
Keywords
CdTe , detector array , pixel , matrix
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
2001
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Record number
2188830
Link To Document