Abstract
Room-temperature semiconductor detectors such as CdTe and CdZnTe have been used in the field of nuclear safeguards to characterise spent fuel (SFAT, Gamma-Taucher), to determine the uranium enrichment and to verify the unirradiated nuclear fuel. The energy resolution of these detectors is lower than for a typical germanium detector but significantly better than for a sodium iodide detector. An incomplete charge collection leads to spectral distortion manifested by asymmetric full-energy peaks and long low-energy tails. The interpretation of the spectra obtained with a CdTe or a CdZnTe detector requires correspondingly accurate knowledge of the analytical line shape. In the present work, the spectral response of a hemispherical CZT (10×10×5 mm3) detector is described with a set of functions (GPP code, J. L. Campbell). The fit parameters have been determined with standard γ sources thus covering the energy range 121–1332 keV. Point sources in different experimental conditions (background, shielding) have been used to simulate spent fuel spectra. Applying the fixed fit parameters, the ratio 134Cs/137Cs has been determined with a good precision.
Keywords
Gamma Spectrometry , CZT detector , Peak fitting , 134Cs/137Cs ratio , Burn-up
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
2001
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Record number
2188867
Link To Document