• Title of article

    Source size conserving broad band monochromators of fixed exit geometry for high energy synchrotron radiation

  • Author/Authors

    Lienert، نويسنده , , U. and Keitel، نويسنده , , S. and Caliebe، نويسنده , , W. and Schulze-Briese، نويسنده , , C. and Poulsen، نويسنده , , H.F.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2001
  • Pages
    4
  • From page
    659
  • To page
    662
  • Abstract
    The degradation of the effective source size by energy tunable, fixed exit, broad band monochromators for high energy synchrotron radiation (40–100 keV) is measured to be below 2 μrad. Two monochromator schemes consisting of either two bent Laue crystals or two SiGe gradient crystals in a non-dispersive setting are characterized. The relative energy bandwidth is about 0.1% and reflectivities are above 80%. The source size broadening and band widths are found to be in agreement with predictions by a kinematical model.
  • Keywords
    Synchrotron radiation , High energy X-rays , X-ray monochromator , Source size broadening , X-ray optics
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    2001
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number