• Title of article

    High-order harmonic suppression by a glass capillary array

  • Author/Authors

    Erko، نويسنده , , A. and Langhoff، نويسنده , , N. and Bjeoumikhov، نويسنده , , A.A. and Beloglasov، نويسنده , , V.I.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2001
  • Pages
    4
  • From page
    832
  • To page
    835
  • Abstract
    A glass capillary array with a rectangular cross-section of each individual capillary has been tested as a high-harmonic suppressor for synchrotron radiation beamlines. Using double reflection in the capillary, the high harmonics of a double-crystal Si (1 1 1) monochromator were reduced by a factor of 10−4–10−5 from their initial value. The beam spread due to glass surface roughness was measured to be ∼30 arcsec. A first harmonic transmission efficiency of 35% was measured at 7500 eV.
  • Keywords
    Synchrotron radiation , Capillary optics , Beamline optics
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    2001
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number