Title of article
High-order harmonic suppression by a glass capillary array
Author/Authors
Erko، نويسنده , , A. and Langhoff، نويسنده , , N. and Bjeoumikhov، نويسنده , , A.A. and Beloglasov، نويسنده , , V.I.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2001
Pages
4
From page
832
To page
835
Abstract
A glass capillary array with a rectangular cross-section of each individual capillary has been tested as a high-harmonic suppressor for synchrotron radiation beamlines. Using double reflection in the capillary, the high harmonics of a double-crystal Si (1 1 1) monochromator were reduced by a factor of 10−4–10−5 from their initial value. The beam spread due to glass surface roughness was measured to be ∼30 arcsec. A first harmonic transmission efficiency of 35% was measured at 7500 eV.
Keywords
Synchrotron radiation , Capillary optics , Beamline optics
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
2001
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Record number
2192149