Title of article
Upgraded DAQ system for the HyperCP experiment
Author/Authors
White، نويسنده , , C.G and Jones، نويسنده , , T.D and Luebke، نويسنده , , W.R. and Chen، نويسنده , , Y.C. and Cheng، نويسنده , , K.C and Choong، نويسنده , , W.S and Kaplan، نويسنده , , D.M. and Nelson، نويسنده , , K and Rubin، نويسنده , , H.A and Turko، نويسنده , , B and Zyla، نويسنده , , P، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2001
Pages
19
From page
67
To page
85
Abstract
The 1999 run of Fermilab E871 (HyperCP) recorded 80 Terabytes of data on 19,000 8 mm tapes with a typical trigger rate near 100 kHz. The readout electronics digitized data from 21,000 input channels with a fixed deadtime of 1.7 μs resulting in a typical livetime of 80%. The typical instantaneous rate of data generated by the HyperCP spectrometer was 36 MB/s. These data were written to tape at a sustained rate of 27 MB/s.
Keywords
Hyperon , E871 , CP violation , DAQ , Acquisition , HyperCP