Title of article
Real-time pulse-shape discrimination and beta–gamma coincidence detection in field-programmable gate array
Author/Authors
Farsoni، نويسنده , , A.T. and Alemayehu، نويسنده , , B. and Alhawsawi، نويسنده , , A. and Becker، نويسنده , , E.M.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2013
Pages
8
From page
75
To page
82
Abstract
A real-time FPGA-based algorithm has been developed and tested to discriminate pulse-shapes, identify beta–gamma coincidence events and collect energy spectra from xenon radioisotopes using a phoswich detector. The detector consists of a thin plastic scintillator (BC-400) to detect beta and conversion electrons, a CsI(Tl) crystal for measuring X-rays and gamma-rays, and a BGO crystal, which surrounds the CsI(Tl) layer, to identify scattered photons and ultimately to reduce Compton continuum in the gamma energy spectrum. In this paper, we report on the detail of the FPGA hardware design, the pulse-shape discrimination method, and the systemʹs operational modes. In addition, our initial real-time radioxenon measurement results with the phoswich detector are presented.
Keywords
digital signal processing , Phoswich detector , Radioxenon measurement , Pulse shape discrimination , FPGA devices
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
2013
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Record number
2193970
Link To Document