Title of article
Resonance capture γ-ray spectrometry at Lead Slowing-down Neutron Spectrometer
Author/Authors
Pourimani، نويسنده , , R and Olejniczak، نويسنده , , U and Popov، نويسنده , , Yu.P and Przytula، نويسنده , , M and Wojtkiewicz، نويسنده , , R، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2002
Pages
14
From page
226
To page
239
Abstract
A new method of measurement of the γ-ray spectra from resonance neutron capture that can be realized at Lead Slowing-down Neutron Spectrometers was proposed and tested experimentally. The specific feature of the method is the shielding of germanium detector by a “thick” investigated sample that absorbs intensive neutron flux with energies corresponding to sample resonances. In these energy regions the detector response on neutron irradiation is considerably reduced while the sample γ-ray spectra are greatly strengthened. The detector response γ-ray spectra are presented and analysed, and the spectra from neutron capture in tantalum resonances at energies 4.28 and 10.36 eV are shown. The obtained results demonstrate the usefulness of the proposed method.
ew excited levels in germanium isotopes are proposed.
Keywords
Capture ?-ray spectrometry , Resonance shielding , Resonance neutrons
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
2002
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Record number
2197097
Link To Document