Application of avalanche photodiode for soft X-ray pulse-height analyses in the Ht-7 tokamak
Author/Authors
Shi، نويسنده , , Yuejiang and Wan، نويسنده , , Baonian and Hu، نويسنده , , Liqun and Sun، نويسنده , , Yanjun and Liu، نويسنده , , Sheng and Ling، نويسنده , , Bili، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2002
Pages
6
From page
566
To page
571
Abstract
An avalanche photodiode (APD) has been used as soft X-ray energy pulse-height analysis system for the measurement of the electron temperature on the HT-7 tokamak. The experimental results obtained with the APD with its inferior energy resolution show a little difference compared to the conventional high energy-resolution Si (Li) detector. Both numerical analysis and experimental results prove that the APD is good enough for application of the electron temperature measurement in tokamaks.
Keywords
APD , PHA , tokamak