Title of article
A readout system for the STAR time projection chamber
Author/Authors
Anderson، نويسنده , , M. and Bieser، نويسنده , , F. and Bossingham، نويسنده , , R. and Cebra، نويسنده , , D. and Hjort، نويسنده , , E.L. and Klein، نويسنده , , S.R. and Kleinfelder، نويسنده , , S. and Vu، نويسنده , , C.Q. and Wieman، نويسنده , , H.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2003
Pages
13
From page
679
To page
691
Abstract
We describe the readout electronics for the STAR Time Projection Chamber. The system is made up of 136,608 channels of waveform digitizer, each sampling 512 time samples at 6–12 Mega-samples per second. The noise level is about 1000 electrons, and the dynamic range is 800:1, allowing for good energy loss (dE/dx) measurement for particles with energy losses up to 40 times minimum ionizing. The system is functioning well, with more than 99% of the channels working within specifications.
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
2003
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Record number
2198154
Link To Document