• Title of article

    Field emission gun for X-ray tubes

  • Author/Authors

    Baturin، نويسنده , , A.S. and Trufanov، نويسنده , , A.I. and Chadaev، نويسنده , , N.N. and Sheshin، نويسنده , , E.P.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2006
  • Pages
    3
  • From page
    253
  • To page
    255
  • Abstract
    The attempt to replace hot cathode with field emission cathode in a commercial X-ray tube have been made. We are continuing investigation of emission properties of the carbon fibers. Cathodes for X-ray tube were made from bundle of carbon fibers. The prototype provides 0.1 mA with focus spot about ∅2 mm under continued 40 kV mode. Each tube contain cathode made of single fibers bundle. The matrix cathode to increase total tube current up to 10 mA/cm2 for macro cathode structure is also considered.
  • Keywords
    X-Ray , Field emission , Carbon fiber
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    2006
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number