• Title of article

    Silica aerogel radiators for bunch length measurements

  • Author/Authors

    Bنhr، نويسنده , , J. and Djordjadze، نويسنده , , V. and Lipka، نويسنده , , D. and Onuchin، نويسنده , , A. and Stephan، نويسنده , , F.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2005
  • Pages
    11
  • From page
    597
  • To page
    607
  • Abstract
    Cherenkov radiators based on silica aerogel are used to measure the electron bunch length at the photo injector test facility at DESY Zeuthen (PITZ). The energy range of those electrons is 4–5 MeV. In this paper, the time resolution defined by the usage of aerogel is calculated analytically and Monte Carlo simulations are performed. It is shown that silica aerogel gives the possibility to reach a time resolution of about 0.1 ps for high photon intensities and a time resolution of about 0.02 ps can be obtained for thin silica aerogel radiators.
  • Keywords
    Silica aerogel , Bunch length , Time resolution , PITZ
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    2005
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number

    2203097