Title of article
Temporal structure of resonator output in a millimeter-wave prebunched FEL
Author/Authors
Shibata، نويسنده , , Yukio and Ishi، نويسنده , , Kimihiro and Takahashi، نويسنده , , Toshiharu and Matsuyama، نويسنده , , Tomochika، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2004
Pages
5
From page
157
To page
161
Abstract
A short-bunched beam of electrons of an L-band linac of 38 MeV is guided to a cylindrical-closed resonator. Wavepackets of coherent transition radiation (CTR) generated from bunches passing through the mirrors are coherently summed up in the resonator. The amplification of the output of the resonator is confirmed in comparison with spontaneous CTR. The temporal structure of the output, observed with a hot-electron bolometer having the response time of 0.35 μs, shows oscillating characteristic of about 1 μs in time scale. The result strongly suggests the inter-bunch distance varies rapidly over the duration of a macropulse, and it consequently results in degradation of the coherent summing up in the resonator.
Keywords
Coherent transition radiation , Millimeter wave , Prebunched FEL
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
2004
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Record number
2203199
Link To Document