• Title of article

    Radiation shielding of high-energy neutrons in SAD

  • Author/Authors

    Seltborg، نويسنده , , P. and Polanski، نويسنده , , A. and Petrochenkov، نويسنده , , S. and Lopatkin، نويسنده , , A. and Gudowski، نويسنده , , W. and Shvetsov، نويسنده , , V.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2005
  • Pages
    16
  • From page
    313
  • To page
    328
  • Abstract
    The radiation fields and the effective dose at the Sub-critical Assembly in Dubna (SAD) have been studied with the Monte Carlo code MCNPX. The effective dose above the shielding, i.e. in the direction of the incident proton beam of 3.0 μA, was found to be about 190 μSv h−1. This value meets the dose limits according to Russian radiation protection regulations, provided that access to the rooms in this area is not allowed for working personnel during operation. arating the radiation fields into a spallation- and a fission-induced part, it was shown that the neutrons with energy higher than 10 MeV, originating exclusively from the proton-induced spallation reactions in the target, contribute for the entire part of the radiation fields and the effective dose at the top of the shielding. Consequently, the effective dose above the SAD reactor system is merely dependent on the proton beam properties and not on the reactivity of the core.
  • Keywords
    ADS , sub-critical , High-energy neutrons , MCNPX , effective dose , SAD
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    2005
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number