• Title of article

    The cryogenic target for the experiment at Jefferson lab

  • Author/Authors

    Covrig، نويسنده , , S.D. and Beise، نويسنده , , E.J. and Carr، نويسنده , , R. and Gustafsson، نويسنده , , K.K. and Hannelius، نويسنده , , L. and Herda، نويسنده , , M.-C. and Jones، نويسنده , , Ce Feng Liu، نويسنده , , J. and McKeown، نويسنده , , R.D. and Neveling، نويسنده , , R. and Rauf، نويسنده , , A.W. and Smith، نويسنده , , G.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2005
  • Pages
    18
  • From page
    218
  • To page
    235
  • Abstract
    A cryogenic horizontal single loop target has been designed, built, tested and operated for the G 0 experiment in Hall C at Jefferson Lab. The target cell is 20 cm long, the loop volume is 6.5 l and the target operates with the cryogenic pump fully immersed in the fluid. The target has been designed to operate at 30 Hz rotational pump speed with either liquid hydrogen or liquid deuterium. The high-power heat exchanger is able to remove 1000 W of heat from the liquid hydrogen, while the nominal electron beam with current of 40 μ A and energy of 3 GeV deposits about 320 W of heat into the liquid. The increase in the systematic uncertainty due to the liquid hydrogen target is negligible on the scale of a parity violation experiment. The global normalized yield reduction for 40 μ A beam is about 1.5% and the target density fluctuations contribute less than 238 ppm (parts per million) to the total asymmetry width, typically about 1200 ppm, in a Q 2 bin.
  • Keywords
    liquid hydrogen target , Density variations , Unpolarized targets , parity violation
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    2005
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number