Title of article
Minimizing guard ring dead space in silicon detectors with an n-type guard ring at the edge of the detector
Author/Authors
Palviainen، نويسنده , , Tanja and Tuuva، نويسنده , , Tuure and Leinonen، نويسنده , , Kari، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2007
Pages
3
From page
277
To page
279
Abstract
Detectors with n-type silicon with an n+-type guard ring were investigated. In the present work, a new p+/n/n+ detector structure with an n+ guard ring is described. The guard ring is placed at the edge of the detector. The detector depletion region extends also sideways, allowing for signal collection very close to the n-guard ring. In this kind of detector structure, the dead space of the detector is minimized to be only below the guard ring. This is proved by simulations done using Silvaco/ATLAS software.
Keywords
Simulation of detector , Guard ring , Detector characterization , Dead space , Silicon-based detector
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
2007
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Record number
2205588
Link To Document