• Title of article

    Variability of the minimum detectable energy of an APD as an electron detector

  • Author/Authors

    Kasahara، نويسنده , , Shyam S. and Takashima، نويسنده , , T. and Hirahara، نويسنده , , M.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2012
  • Pages
    7
  • From page
    282
  • To page
    288
  • Abstract
    The purpose of this study is to evaluate the variability of the minimum detectable energy of the avalanche photodiode which would be applied for measurements of medium-energy ( ∼ 10 – 100 keV ) electrons in future magnetospheric exploration. The minimum detectable energy is affected by temperature variations as well as radiation. Our experiments and theoretical considerations show that the minimum detectable energy is significantly deteriorated at room temperature after proton irradiation of > 10 krad mainly due to an increase in the dark current, whereas such a degradation is less prominent when the device is cooled down to < 5 ° C . These results provide a guideline for the thermal design of the medium-energy electron instruments especially for harsh-radiation space missions.
  • Keywords
    space physics , Electron measurements , Planetary magnetospheres , Avalanche photodiode