Title of article
Algorithms for pulse shape analysis using silicon detectors
Author/Authors
Liddick، نويسنده , , S.N. and Darby، نويسنده , , I.G. and Grzywacz، نويسنده , , R.K.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2012
Pages
9
From page
70
To page
78
Abstract
The development of digital electronics and their application to nuclear spectroscopy has provided an opportunity to perform experiments beyond the technical capabilities of analog systems. The pulse-shape analysis of Si detectors is described here for the selective identification of pile-up pulses resulting from the sequential alpha decay of 109Xe and 105Te isotopes. A two stage offline pulse shape analysis algorithm is described which is able to detect pile-up pulses from the two alpha decays with time differences between the two individual pulses as low as 100 ns over a wide range of relative amplitudes.
Keywords
Decay spectroscopy , Silicon detectors , Digital electronics