• Title of article

    Determination of the axial thermal neutron flux non-uniform factor in the MNSR inner irradiation capsule

  • Author/Authors

    Khattab، نويسنده , , K. and Ghazi، نويسنده , , N. Ben Omar، نويسنده , , H.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    5
  • From page
    456
  • To page
    460
  • Abstract
    A 3-D neutronic model, using the WIMSD4 and CITATION codes, for the Syrian Miniature Neutron Source Reactor (MNSR) is used to calculate the axial thermal neutron flux non-uniform factor in the inner irradiation capsule. The calculated result is 4%. A copper wire is used to measure the axial thermal neutron flux non-uniform factor in the inner irradiation capsule to be compared with the calculated result. The measured result is 5%. Good agreement between the measured and calculated results is obtained.
  • Keywords
    MNSR , Non-uniform factor , Irradiation capsule
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    2007
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number