Title of article
Determination of the axial thermal neutron flux non-uniform factor in the MNSR inner irradiation capsule
Author/Authors
Khattab، نويسنده , , K. and Ghazi، نويسنده , , N. Ben Omar، نويسنده , , H.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2007
Pages
5
From page
456
To page
460
Abstract
A 3-D neutronic model, using the WIMSD4 and CITATION codes, for the Syrian Miniature Neutron Source Reactor (MNSR) is used to calculate the axial thermal neutron flux non-uniform factor in the inner irradiation capsule. The calculated result is 4%. A copper wire is used to measure the axial thermal neutron flux non-uniform factor in the inner irradiation capsule to be compared with the calculated result. The measured result is 5%. Good agreement between the measured and calculated results is obtained.
Keywords
MNSR , Non-uniform factor , Irradiation capsule
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
2007
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Record number
2205994
Link To Document