• Title of article

    A new fast two-stage GL charge division method for a very long MSGC for large-area radiation imaging

  • Author/Authors

    Siritiprussamee، نويسنده , , P. and Fujita، نويسنده , , K. and Takahashi، نويسنده , , H. and Niko، نويسنده , , H. and Nishi، نويسنده , , K. and Toyokawa، نويسنده , , H. and Furusaka، نويسنده , , M. and Ino، نويسنده , , T. and Kishimoto، نويسنده , , S. and Shimizu، نويسنده , , H.M. and Kanazawa، نويسنده , , M.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    4
  • From page
    1119
  • To page
    1122
  • Abstract
    We present a novel readout method; a fast two-stage Global Local (GL) charge division method. The new readout method is to utilize two coincident signals to localize position. It can greatly improve a spatial resolution when applies to a high signal-to-noise ratio (SNR) detector. We have implemented the new readout method in very long microstrip gas counters (MSGCs). Prototype detectors, which have 640.8 mm of an active length, have been designed, fabricated and evaluated. The principle of the new readout method was confirmed. The spatial resolution was 1.15 mm with good uniformity and good linearity.
  • Keywords
    Position sensitive detector , Gas detector , MSGC , Two-stage GL charge division method , Readout method
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    2007
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number