Title of article
A multi-detector neutron spectrometer with nearly isotropic response for environmental and workplace monitoring
Author/Authors
Gَmez-Ros، نويسنده , , J.M. and Bedogni، نويسنده , , R. and Moraleda، نويسنده , , M. and Delgado، نويسنده , , A. and Romero، نويسنده , , A. and Esposito، نويسنده , , A.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2010
Pages
7
From page
127
To page
133
Abstract
This communication describes an improved design for a neutron spectrometer consisting of 6Li thermoluminescent dosemeters located at selected positions within a single moderating polyethylene sphere. The spatial arrangement of the dosemeters has been designed using the MCNPX Monte Carlo code to calculate the response matrix for 56 log-equidistant energies from 10−9 to 100 MeV, looking for a configuration that permits to obtain a nearly isotropic response for neutrons in the energy range from thermal to 20 MeV. The feasibility of the proposed spectrometer and the isotropy of its response have been evaluated by simulating exposures to different reference and workplace neutron fields. The FRUIT code has been used for unfolding purposes. The results of the simulations as well as the experimental tests confirm the suitability of the prototype for environmental and workplace monitoring applications.
Keywords
neutron dosimetry , Neutron spectrometry , Unfolding
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
2010
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Record number
2209387
Link To Document