• Title of article

    The Light-Pulser Monitoring System for the WASA detector facility

  • Author/Authors

    Zabierowski، نويسنده , , J. and Rachowski، نويسنده , , J.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2009
  • Pages
    8
  • From page
    411
  • To page
    418
  • Abstract
    The design and performance of the system for monitoring the stability of the scintillation counters in the WASA multi-detector apparatus are presented. The system utilizes light pulses generated by LEDs and a Xenon flash tube, for monitoring plastic and inorganic scintillator based counters, respectively.
  • Keywords
    Scintillation detectors , Monitoring the detector stability , LED pulser
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    2009
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number