• Title of article

    The C4F10 Cherenkov detector for DIRAC-II

  • Author/Authors

    Horikawa، نويسنده , , S. and Allkofer، نويسنده , , Y. and Amsler، نويسنده , , C. and Brekhovskikh، نويسنده , , V. M. Kuptsov، نويسنده , , A. and Pentia، نويسنده , , M. and Zhabitsky، نويسنده , , M.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2008
  • Pages
    4
  • From page
    212
  • To page
    215
  • Abstract
    A new threshold Cherenkov detector using C4F10 gas radiator was built and put into operation in the DIRAC-II experiment at CERN. Running on the C4F10 at room temperature and atmospheric pressure, the detector discriminates between pions and kaons in the momentum range of 4– 8 GeV / c . A compact radiator–gas recirculation system including a gas–liquid separation unit, hollow-fibre membranes and molecular sieves ensures gas purity for a long term of operation without a significant loss of the gas. The system is robust and stable and the pressure in the two detector vessels is regulated in the range of ± 0.5 mbar . We report on the design and the technical aspects of the detector and its response in the DIRAC 2007 run.
  • Keywords
    Particle identification , Fluorocarbons
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    2008
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number

    2210326