• Title of article

    The maximum likelihood reconstruction method for JET neutron tomography

  • Author/Authors

    Craciunescu، نويسنده , , T. and Bonheure، نويسنده , , G. and Kiptily، نويسنده , , V. and Murari، نويسنده , , A. and Soare، نويسنده , , S. and Tiseanu، نويسنده , , I. and Zoita، نويسنده , , V.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2008
  • Pages
    8
  • From page
    623
  • To page
    630
  • Abstract
    The JET neutron profile monitor ensures coverage of the neutron emissive region that enables tomographic reconstruction. However, due to the availability of only two projection angles and to the coarse sampling, tomography is a limited data set problem. A reconstruction method based on the maximum likelihood principle is developed for solving the reconstruction problem. A smoothing operator, defined as median filtering which uses a sliding window moving along magnetic contour lines, is used to compensate for the lack of experimental information. The method is tested on numerically simulated phantoms with shapes characteristic for this kind of tomography. Significant reconstructions of experimental data are reported.
  • Keywords
    Maximum likelihood tomography , Tokamak neutron plasma diagnostics
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    2008
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number