• Title of article

    Measurement of anomalously high charge collection efficiency in n+p strip detectors irradiated by up to 1016 neq/cm2

  • Author/Authors

    Mandi?، نويسنده , , Igor and Cindro، نويسنده , , Vladimir and Kramberger، نويسنده , , Gregor and Miku?، نويسنده , , Marko، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2009
  • Pages
    5
  • From page
    263
  • To page
    267
  • Abstract
    Micro-strip detectors made by implanting n-type readout strips on p-type silicon bulk (n+p) are promising candidates for tracking detectors for applications in extremely high radiation fields such as those expected in experiments at Super-LHC. In this paper, we present measurements of signals in n+p strip detectors caused by fast electrons from a 90Sr source and read out by an SCT128A chip. Detectors were irradiated with reactor neutrons up to 1016 neq/cm2. The collected charge was measured at different bias voltages, and measurements were taken up to very high voltages of 1700 V. We measured the most probable value of collected charge as high as before irradiation with detectors irradiated up to 3×1015 neq/cm2. Excellent performance with nearly 50% of the charge collected was also obtained with the detector irradiated to 1016 neq/cm2.
  • Keywords
    p-Type silicon , Micro-strip detectors , Radiation hardness , Super LHC
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    2009
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number

    2211123