• Title of article

    Energy-dependent neutron imaging with a double crystal monochromator at the ANTARES facility at FRM II

  • Author/Authors

    Schulz، نويسنده , , Michael and Bِni، نويسنده , , Peter and Calzada، نويسنده , , Elbio and Mühlbauer، نويسنده , , Martin and Schillinger، نويسنده , , Burkhard، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2009
  • Pages
    3
  • From page
    33
  • To page
    35
  • Abstract
    A double crystal-type monochromator has been installed at the ANTARES facility at FRM II, Munich, close to the collimator where the beam size is still only a few centimetres. Using this new set-up, it is now possible to perform high-resolution monochromatic neutron imaging in a wavelength range from 2.7 to 6.5 Å with a wavelength resolution Δλ/λ of 4–1%. Most of the Bragg edges of materials of interest for neutron radiography lie in this wavelength region. Exposure times in the order of 300 s per radiograph are feasible with this new set-up.
  • Keywords
    Energy selective imaging , Neutron radiography , Double crystal monochromator
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    2009
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number