Title of article
Mechanical properties of bovine cortical bone at high strain rate
Author/Authors
Ferreira، نويسنده , , F. Cortez Vaz، نويسنده , , M.A. and Simُes، نويسنده , , J.A.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2006
Pages
9
From page
71
To page
79
Abstract
Intense investigation has been performed to characterize static and dynamic mechanical properties of trabecular and cortical bone. The Split Hopkinson Pressure Bar (SHPB) technique has been applied with success in the study of mainly other engineering materials, and constitutive laws concerning the dynamical behaviour of these have been derived. This paper describes the characterization of mechanical properties of fresh bovine cortical bone at different high strain rate using the SHPB method. Cube specimens of dimensions 10 × 10 × 10 mm of bone were prepared according to longitudinal and transverse directions. The differences of results for ultimate strength (max. 281 MPa; min. 240 MPa), strain at fracture (max. 45.3 mm/m; min. 32.6 mm/m) and elastic modulus (max. 9.9 GPa; min. 6.8 GPa) in these directions were not statistically significant. Overall, for both longitudinal and transverse directions the elastic modulus decreased and the ultimate strength increased for higher strain rates.
Keywords
high strain rate , Elastic modulus , Bovine bone , Ultimate strength , Hopkinson Bar
Journal title
Materials Characterization
Serial Year
2006
Journal title
Materials Characterization
Record number
2266270