• Title of article

    Air entrainment rate and holdup in the Jameson cell

  • Author/Authors

    Ta?demir، نويسنده , , T. and ?teyaka، نويسنده , , B. and Ta?demir، نويسنده , , A.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    5
  • From page
    761
  • To page
    765
  • Abstract
    Air entrainment rate and holdup are important and potential control parameters in plunging liquid jet bubble columns. In this study, air entrainment and holdup in laboratory Jameson cell downcomer were investigated in an air–water system. Air entrainment flow rates and holdup were quantified experimentally. The effects of various conditions in the nozzle diameter, the downcomer diameter, the free jet length, the jet velocity and the ratio of air-feed flow rate on gas holdup and air entrainment were studied. Two empirical equations were proposed to estimate gas holdup. The predictions from these equations are in good agreement with the experimental data for holdup.
  • Keywords
    Holdup , Air entrainment , Jameson cell , Plunging jet column
  • Journal title
    Minerals Engineering
  • Serial Year
    2007
  • Journal title
    Minerals Engineering
  • Record number

    2274975