Title of article
Air entrainment rate and holdup in the Jameson cell
Author/Authors
Ta?demir، نويسنده , , T. and ?teyaka، نويسنده , , B. and Ta?demir، نويسنده , , A.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2007
Pages
5
From page
761
To page
765
Abstract
Air entrainment rate and holdup are important and potential control parameters in plunging liquid jet bubble columns. In this study, air entrainment and holdup in laboratory Jameson cell downcomer were investigated in an air–water system. Air entrainment flow rates and holdup were quantified experimentally. The effects of various conditions in the nozzle diameter, the downcomer diameter, the free jet length, the jet velocity and the ratio of air-feed flow rate on gas holdup and air entrainment were studied. Two empirical equations were proposed to estimate gas holdup. The predictions from these equations are in good agreement with the experimental data for holdup.
Keywords
Holdup , Air entrainment , Jameson cell , Plunging jet column
Journal title
Minerals Engineering
Serial Year
2007
Journal title
Minerals Engineering
Record number
2274975