• Title of article

    Use of temperature for diagnosing mixing in the IsaMill

  • Author/Authors

    Gunda، نويسنده , , R. and Moys، نويسنده , , M.H.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2015
  • Pages
    9
  • From page
    100
  • To page
    108
  • Abstract
    This paper describes a methodology to monitor axial mixing in an IsaMill as a function of mill feed flow rate, mill tip speed and media load. Steady state temperature measurements (profiles) along the mill length were used to quantify the degree of mixing during the comminution process. Combined mass and energy balances across the mill length were done to develop a predictive model for slurry mixing in the mill. The temperature measurements can be used for IsaMill control and optimisation.
  • Keywords
    Optimisation , Process control , comminution , model , Ultrafine grinding
  • Journal title
    Minerals Engineering
  • Serial Year
    2015
  • Journal title
    Minerals Engineering
  • Record number