Title of article
The mechanical properties of nanofilled resin-based composites: The impact of dry and wet cyclic pre-loading on bi-axial flexure strength
Author/Authors
Curtis، نويسنده , , Andrew R. and Palin، نويسنده , , William M. and Fleming، نويسنده , , Garry J.P. and Shortall، نويسنده , , Adrian C.C. and Marquis، نويسنده , , Peter M.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2009
Pages
10
From page
188
To page
197
Abstract
Objectives
ermine the influence of nano-sized filler particles and agglomerates of nanoparticles (‘nanoclusters’) in resin-based composite (RBC) materials on the bi-axial flexure strength (BFS) following cyclic pre-loading and storage in a ‘dry’ or ‘wet’ environment.
commercially available RBC restoratives, Heliomolar (Ivoclar Vivadent, Schaan, Liechtenstein), Z100 MP Restorative, Filtek™ Z250, Filtek™ Supreme (3M ESPE, St. Paul, MN, USA) in Body (FSB) and Translucent (FST) shades, Grandio and Grandio Flow (VOCO, Cuxhaven, Germany), containing differing filler particle types and morphologies were investigated. Specimens were pre-loaded at 20, 50 or 100 N for 2000 cycles and stored in a ‘dry’ or ‘wet’ environment prior to BFS testing.
s
ral linear model analysis of variance highlighted a reduction in the BFS following pre-loading, however, individual RBC materials responded differently. The RBCs containing agglomerated nano-sized particles or ‘nanoclusters’ (Filtek™ Supreme) demonstrated distinctive and unique patterns of response to pre-loading. Cyclic pre-loading at 20 and 50 N significantly increased the Weibull modulus of both FSB (8.53 ± 1.91 and 10.23 ± 2.29) and FST (16.89 ± 3.78 and 10.91 ± 2.45) compared with FSB and FST control (no pre-cyclic load) specimens (5.98 ± 1.34 and 7.99 ± 1.78, respectively). BFS of FSB and FST was maintained or significantly increased compared with the other materials following 20 and 50 N cyclic pre-load (P < 0.05).
icance
anoclusters’ provided a distinct reinforcing mechanism compared with the microhybrid, microfill or nanohybrid RBC systems resulting in significant improvements to the strength and reliability, irrespective of the environmental storage and testing conditions. Silane infiltration within interstices of the nanoclusters may modify the response to pre-loading induced stress, thereby enhancing damage tolerance and providing the potential for improved clinical performance.
Keywords
cyclic fatigue , Bi-axial flexure strength , nanofillers , Resin-based composite
Journal title
Defence Technology
Serial Year
2009
Journal title
Defence Technology
Record number
2316972
Link To Document