Title of article
Non-linear elastic three-dimensional finite element analysis on the effect of endocrown material rigidity on alveolar bone remodeling process
Author/Authors
Aversa، نويسنده , , Raffaella and Apicella، نويسنده , , Davide and Perillo، نويسنده , , Letizia and Sorrentino، نويسنده , , Roberto and Zarone، نويسنده , , Fernando Henrique Ferrari Alves، نويسنده , , Marco and Apicella، نويسنده , , Antonio، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2009
Pages
13
From page
678
To page
690
Abstract
Objectives
lthy conditions, modeling and remodeling collaborate to obtain a correct shape and function of bones. Loads on bones cause bone strains which generate signals that some cells can detect and respond to. Threshold ranges of such signals are genetically determined and are involved in the control of modeling and remodeling. The present study aimed at assessing the deformations transferred to surrounding bone by endodontically treated maxillary central incisors restored with endocrowns made up of high or low elastic modulus materials.
s
lid model consisted of a maxillary central incisor, the periodontal ligament (PDL) and the surrounding cortical and cancellous bone. Both composite and alumina endocrowns were simulated under load and compared to a sound tooth. Dynamic non-linear analyses were performed to validate discretization processes. Non-linear analyses were performed on teeth and surrounding bone to estimate strain variations according to restorative techniques.
s
values in cortical bone, spongy bone, alveolar cortex and tooth were evaluated. PDL allowed models to homogeneously transfer loads to bone. Strains developing in highly rigid restorations were estimated to activate bone modeling and remodeling.
icance
gher deformability of composites could enable restorative systems to transfer limited strains to compact and spongy bone of tooth socket. Although composites could not prevent the physiological resorption of the alveolar bone, they could successfully reduce strain arising in tooth socket when compared to alumina. The PDL prevented bone to undergo high deformations, resulting in natural flexural movements of teeth.
Keywords
Maxilla , endodontically treated teeth , STRAIN GAUGE , Validation , FEA , Finite element analysis , Endocrown