Title of article
Energy efficiency in pumps
Author/Authors
Kaya، نويسنده , , Durmus and Yagmur، نويسنده , , E. Alptekin and Yigit، نويسنده , , K. Suleyman and Kilic، نويسنده , , Fatma Canka and Eren، نويسنده , , A. Salih and Celik، نويسنده , , Cenk، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2008
Pages
12
From page
1662
To page
1673
Abstract
In this paper, “energy efficiency” studies, done in a big industrial facility’s pumps, are reported. For this purpose; the flow rate, pressure and temperature have been measured for each pump in different operating conditions and at maximum load. In addition, the electrical power drawn by the electric motor has been measured. The efficiencies of the existing pumps and electric motor have been calculated by using the measured data.
ial energy saving opportunities have been studied by taking into account the results of the calculations for each pump and electric motor. As a conclusion, improvements should be made each system. The required investment costs for these improvements have been determined, and simple payback periods have been calculated.
in energy saving opportunities result from: replacements of the existing low efficiency pumps, maintenance of the pumps whose efficiencies start to decline at certain range, replacements of high power electric motors with electric motors that have suitable power, usage of high efficiency electric motors and elimination of cavitation problems.
Keywords
Energy Savings , Energy efficiency , PUMP