• Title of article

    Mechanical and experimental study on freeze proof solar powered adsorption cooling tube using active carbon/methanol working pair

  • Author/Authors

    Zhao، نويسنده , , Huizhong and Zhang، نويسنده , , Min and Zhenyan، نويسنده , , Liu and Yanling، نويسنده , , Liu and Xiaodong، نويسنده , , Ma، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2008
  • Pages
    5
  • From page
    2434
  • To page
    2438
  • Abstract
    The freeze proof solar cooling tube, which can produce cooling capacity with the refrigerant temperature below 0 °C using solar light as energy and active carbon–methanol as working pair, was firstly designed and made in this research. This paper focused on mechanical and experimental study on a freeze proof solar powered adsorption cooling tube. The following experimental results could be concluded: at the solar radiation value between 15.3 and 17.1 MJ m−2, the highest adsorbent bed temperature is below 110 °C. The freeze proof solar cooling tube’s cooling capacity was about 87–99 kJ, and the coefficient of performance (COP) was more than 0.11 when the evaporation temperature was about −4 °C.
  • Keywords
    Active carbon/methanol , Freeze proof , Adsorption refrigeration , COP
  • Journal title
    Energy Conversion and Management
  • Serial Year
    2008
  • Journal title
    Energy Conversion and Management
  • Record number