Title of article
Experimental study of diffusion flame oscillations and empirical correlations
Author/Authors
Yilmaz، نويسنده , , Nadir and Burl Donaldson، نويسنده , , A. and Edward Lucero، نويسنده , , R.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2008
Pages
5
From page
3287
To page
3291
Abstract
A diagnostic tool, the cadmium sulfide photocell, was used to study flame oscillation. This light sensitive device proved to be relatively accurate and cheap for measuring flame oscillations. This was done by measuring the light variations associated with – and as a result of – flame oscillation or flicker.
speculated that the flame flow conditions and mechanisms responsible for flame oscillations are highly sensitive to various burner configurations. In the study, various burner configurations were placed inside an enclosure and the resulting flame oscillation frequency was measured. Considered were: (a) size of slot burner orifice, (b) size of slot burner nominal diameter, and (c) gas supply flow rate. Each of these variables was changed to determine whether the flame oscillation frequency followed the Von Karman vortex shedding or other models. It was shown that there is a strong relation between St and Fr numbers.
Keywords
Flame oscillation , Photocells , Correlation