Title of article
Design, fabrication and performance tests for a polymer-based flexible flat heat pipe
Author/Authors
Hsieh، نويسنده , , Shou-Shing and Yang، نويسنده , , Ya-Ru، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2013
Pages
10
From page
10
To page
19
Abstract
In this paper, we report on the novel design, fabrication and performance tests for a polymer-based flexible flat heat pipe (FHP) with a bending angle in the range of 15–90°. Each heat pipe is 4 mm thick, 20 mm wide and 80 mm long, with two layers of No. 250 copper mesh as the wicking material. A copper/silicone rubber hybrid structure is designed and fabricated to achieve the flexibility of the heat pipe. Thermal characteristics are measured and studied for de-ionized water under different working conditions. Experimental results reveal that a bending angle of 15° on the vertical plane has a better thermal performance than those of heat pipes with/without bending. In addition, a higher power of 12.67 W can be transferred/delivered.
Keywords
Charge ratio , Thermal Resistance , Flexible heat pipe
Journal title
Energy Conversion and Management
Serial Year
2013
Journal title
Energy Conversion and Management
Record number
2336783