• Title of article

    Analysis of temperature and stress distribution of superheater tubes after attemperation or sootblower activation

  • Author/Authors

    Madejski، نويسنده , , Pawe? and Taler، نويسنده , , Dawid، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2013
  • Pages
    7
  • From page
    131
  • To page
    137
  • Abstract
    Superheaters are characterized by high metal temperatures due to higher steam temperature and low heat transfer coefficients on the tube inner surfaces. Superheaters have especially difficult operating conditions, particularly during attemperator and sootblower activations, when temperature and steam flow rate as well as tube wall temperature change with time. A detailed thermo-mechanical analysis of the superheater tubes makes it possible to identify the cause of premature high-temperature failures and aids greatly in the changes in tubing arrangement and improving start-up technology. This paper presents a thermal and strength analysis of a tube “double omega”, used in the steam superheaters in CFB boilers.
  • Keywords
    Attemperator , Finite volume method , thermal stresses , Steam boiler , Superheater , Sootblower
  • Journal title
    Energy Conversion and Management
  • Serial Year
    2013
  • Journal title
    Energy Conversion and Management
  • Record number