• Title of article

    Rotor current transient analysis of DFIG-based wind turbines during symmetrical voltage faults

  • Author/Authors

    Ling، نويسنده , , Yu and Cai، نويسنده , , Xu and Wang، نويسنده , , Ningbo، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2013
  • Pages
    8
  • From page
    910
  • To page
    917
  • Abstract
    The impact of grid voltage fault on doubly fed induction generators (DFIGs), especially rotor currents, has received much attention. So, in this paper, the rotor currents of based-DFIG wind turbines are considered in a generalized way, which can be widely used to analyze the cases under different levels of voltage symmetrical faults. A direct method based on space vector is proposed to obtain an accurate expression of rotor currents as a function of time for symmetrical voltage faults in the power system. The presented theoretical analysis is simple and easy to understand and especially highlights the accuracy of the expression. Finally, the comparable simulations evaluate this analysis and show that the expression of the rotor currents is sufficient to calculate the maximum fault current, DC and AC components, and especially helps to understand the causes of the problem and as a result, contributes to adapt reasonable approaches to enhance the fault ride through (FRT) capability of DFIG wind turbines during a voltage fault.
  • Keywords
    Doubly fed induction generator (DFIG) , PROTECTION , Wind power generation , Rotor current , Voltage fault
  • Journal title
    Energy Conversion and Management
  • Serial Year
    2013
  • Journal title
    Energy Conversion and Management
  • Record number