• Title of article

    Failure analysis of a silane gas cylinder valve: A case study

  • Author/Authors

    Peng، نويسنده , , Deng-Jr and Chang، نويسنده , , Yo-Yu and Wu، نويسنده , , Hong-Chun and Tsaur، نويسنده , , Charng-Cheng and Chen، نويسنده , , Jenq-Renn Chen، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2008
  • Pages
    6
  • From page
    275
  • To page
    280
  • Abstract
    A tragic fire occurred in a photovoltaic fabrication plant and resulted in one fatality and significant losses in equipment damage and production interruption. Investigation results indicated that failure of a silane cylinder valve was the main cause. Tests which simulate the incident scenario were conducted to find out the cause of the failure. The test results showed that if a retainer was improperly torqued, an operator could remove and detach the retainer from the valve by hand even without using a wrench. The detached retainer resulted in rapid release of silane and caused a significant explosion. Suggestions on the structure design and operation of silane cylinder valve are also given to prevent similar incidents in the future.
  • Keywords
    Fire and explosion , Structure design failure , Silane cylinder valve
  • Journal title
    Engineering Failure Analysis
  • Serial Year
    2008
  • Journal title
    Engineering Failure Analysis
  • Record number