• Title of article

    Modeling and calculation of open carbon dioxide refrigeration system

  • Author/Authors

    Cai، نويسنده , , Yufei and Zhu، نويسنده , , Chunling and Jiang، نويسنده , , Yanlong and Shi، نويسنده , , Hong، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2015
  • Pages
    7
  • From page
    92
  • To page
    98
  • Abstract
    Based on the analysis of the properties of carbon dioxide, an open carbon dioxide refrigeration system is proposed, which is responsible for the situation without external electricity unit. A model of open refrigeration system is developed, and the relationship between the storage environment of carbon dioxide and refrigeration capacity is conducted. Meanwhile, a test platform is developed to simulation the performance of the open carbon dioxide refrigeration system. By comparing the theoretical calculations and the experimental results, several conclusions are obtained as follows: refrigeration capacity loss by heat transfer in supercritical state is much more than that in two-phase region and the refrigeration capacity loss by remaining carbon dioxide has little relation to the state of carbon dioxide. The results will be helpful to the use of open carbon dioxide refrigeration.
  • Keywords
    Supercritical state , Carbon dioxide , Two-phase region , Open refrigeration system , Refrigeration capacity loss
  • Journal title
    Energy Conversion and Management
  • Serial Year
    2015
  • Journal title
    Energy Conversion and Management
  • Record number

    2338752