• Title of article

    Failure of titanium condenser tube

  • Author/Authors

    Shalaby، نويسنده , , H.M. and Al-Mazeedi، نويسنده , , H. and Gopal، نويسنده , , H. and Tanoli، نويسنده , , N.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2011
  • Pages
    8
  • From page
    1990
  • To page
    1997
  • Abstract
    Failure investigation was carried out on a titanium condenser tube that suffered from a large size perforation. The environment at the shell side is hydrocarbon with low pressure steam, while it is seawater at the tube side. The tube was totally plugged with alkaline scale, consisting of calcium carbonate and calcium sulfate. The investigation revealed that in the initial stages of fouling, the titanium tube suffered from erosion–corrosion damage due to the presence of turbulent flow conditions and suspended solids. On the other hand, when the tube became totally fouled, overheating occurred, leading to growth of the oxide film on the internal tube surface. However, the titanium oxide film cracked due to the pressure exerted by the growing scale inside the tube, leading to thin lip rupture.
  • Keywords
    Titanium oxide , Titanium tube , cracking , Crystallization fouling
  • Journal title
    Engineering Failure Analysis
  • Serial Year
    2011
  • Journal title
    Engineering Failure Analysis
  • Record number

    2339423