• Title of article

    Comprehensive reliability analysis of blistered ‘LPG wash water vessel’ in FCC unit – Part I: Failure analysis

  • Author/Authors

    Bhattacharya، نويسنده , , Sova and Chandrasekaran، نويسنده , , Kannan and Lahiri، نويسنده , , A.K.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2013
  • Pages
    7
  • From page
    91
  • To page
    97
  • Abstract
    LPG wash water vessel of INDMAX process unit – an improvised patented FCC technology of Indian Oil Research and Development centre experienced severe hydrogen blistering damage calling for replacement of the wash vessel. Considering the lead time of supply of new vessel, it was decided to carry out Engineering Critical Assessment (ECA) using IOC’s in-house developed software, before taking the vessel in service. The vessel was re-put into service at de-rated operating conditions for a period of more than 6 months and there after the vessel was replaced. It was desired to carry out a detailed investigation on failed vessel post replacement, to find out the root cause analysis and reconfirmation of the ECA methodology adopted for reliability assessment employed during the study. This paper enumerates the findings of the failure analysis carried out on the vessel post replacement. Part-II of the paper describes the detailed ECA analysis carried out during service as well post replacement of the vessel.
  • Keywords
    Hydrogen Blister , lamination , INDMAX process , Metallurgical investigation , LPG wash water vessel
  • Journal title
    Engineering Failure Analysis
  • Serial Year
    2013
  • Journal title
    Engineering Failure Analysis
  • Record number

    2339748